Chapter I.
1. ı˻
1.1 ı˻
1.2 ı˻
1.2.1 ŷڼ
1.2.2
1.2.3
1.3 ⺻
1.4 ǥ ı
2.
2.1
2.2 ŵ
2.3 ؼ
2.3.1 ְǰ
2.3.2 ǰ
2.3.3
2.3.4 ؼ
Chapter II. װ ı˻ ǰý
1. װ ǰý
1.1 װ Ư¡
1.2 װ ǰý
1.2.1 ǰý
1.2.2 װ ǰý ܰ
1.3 ǰý 3
1.4 װ ǰý
1.4.1 AS9100 װ о ǰ濵ý
1.4.2 ΰ ״籹 䱸 ǰ䱸
2. װ Ư
3. Ư 3
3.1 NADCAP ɻ μ
4. ı˻ ڰ
4.1 NAS410 ڰ
4.1.1 ڰ
4.1.2 ڰ䱸
4.1.3 ڰ
Chapter III. ı˻ ̷
1. ںŽ˻, MT(Magnetic particle Testing)
1.1 Ϲ
1.1.1 ⺻
1.1.2 ںŽ˻ з
1.1.3 ںŽ˻ Ư¡
1.1.4 ڱŽ
1.2 ںŽ˻ ̷
1.2.1 ö ڱ
1.2.2 ں
1.2.2.1 ں
1.2.2.2 ں Ư¡
1.3 ںŽ˻
1.3.1 ó
1.3.2 ȭ
1.3.2.1 ȭ
1.3.2.2 ȭ
1.3.2.3 ȭġ
1.3.2.4 ȭ ð
1.3.3 ں
1.3.3.1 ں
1.3.3.2 ǽĹ Ĺ
1.3.3.3 ӹ ܷ
1.3.3.4 ںи ġ
1.3.4
1.3.5 з
1.3.5.1 ǻ Ȯ
1.3.5.2 Ȯε ں
1.3.6 ںи
1.3.7 ó
1.3.7.1 ó ʿ伺
1.3.7.2 ó
1.4 ںŽ˻ ġ
1.4.1 Ž ȭ
1.4.1.1 ذ ϴ ȭ ġ
1.4.1.2 Ϲ ϴ ȭġ
1.4.2 ȭ
1.4.2.1 ˹ ȭ
1.4.2.2 ˹ ȭ
1.4.2.3 ںŽġ
2. ħŽ˻, PT(Penetrant Testing)
2.1 Ϲ
2.1.1 ˻
2.1.2 ħ˻
2.1.3 ħ˻
2.2 ħŽ˻
2.2.1 ħ ħ
2.2.1.1 ǥ(Surface Tension)
2.2.1.2 ɼ(Wetting Ability)
2.2.1.3 (Capillary Action)
2.2.2 ħ
2.2.3
2.2.4
2.3 ħŽ˻ з
2.4 ħŽ
2.4.1 Ϲ ˻
2.4.1.1 ó(Pre-cleaning)
2.4.1.2 ħó(Penetrant Application)
2.4.1.3 ôó(Removal of Excess Penetrant)
2.4.1.4 ó(Developer Application)
2.4.1.5 (Visual Examination)
2.4.1.6 ó(Post-cleaning)
3. 缱 ˻, RT(Radiographic Testing)
3.1 Ϲ
3.1.1 缱
3.1.2 缱 ˻
3.1.3 缱 ˻
3.1.4 缱 ˻ Ư¡
3.2 缱 ˻ ̷
3.2.1 缱
3.2.2 缱
3.2.2.1 ἱ
3.2.2.2 ⼱
3.2.2.3 x 㼱
3.2.3 缱
3.2.3.1 缱 ȣۿ
3.2.3.2 ۿ
3.2.3.3 ۿ
3.2.3.4 ۿ
3.2.4
3.2.4.1 ִ
3.2.4.2 ϵ ִ
3.2.5 ƮƮ 125
3.2.5.1 ʸ ƮƮ
3.2.5.2
3.2.5.3
3.2.5.4 n
3.2.6
3.2.6.1 ĺ Ѱ ƮƮ
3.2.6.2
3.2.6.3 ˻ ȭ ó
3.2.6.4 ȭ ó
3.2.6.5 ̹¡ ÷Ʈ ȭó
3.3 缱 ˻ ġ
3.3.1 缱 ˻ ġ
3.3.1.1 X ˻ ġ
3.3.1.2 㼱 ˻ ġ
3.3.2 缱 ˻
3.3.2.1 X ʸ
3.3.2.2 (ũ)
3.3.2.3
3.3.2.4
3.3.2.5 Ÿ
4. Ž˻, UT(Ultrasonic Testing)
4.1 Ϲ
4.1.1 ˻
4.1.2 Ž
4.1.3 Ž
4.2 Ž˻ ̷
4.2.1
4.2.1.1 (Wavelength, )
4.2.1.2 ӵ(Velocity, v)
4.2.1.3 ļ(Frequency, f)
4.2.1.4 ֱ(Period, T)
4.2.1.5 Ǵ(Acoustic Impedence, Z)
4.2.1.6 Ⱝ(Acoustic Pressure, P, Acoustic Intensity, I)
4.2.2
4.2.2.1 (Longitudinal wave, L-wave)
4.2.2.2 Ⱦ(Transverse Wave, Shear Wave, S-wave)
4.2.2.3 ǥ(Surface Wave, Rayleigh wave)
4.2.2.4 (Plate Wave, Lamb wave)
4.2.3
4.2.4 ŵ
4.2.4.1 (Refraction) ȯ(Mode Conversion)
4.2.4.2 Ư
4.2.4.3 (Attenuation)
4.3 Ž˻
4.3.1 Ž(Ultrasonic Instrument)
4.3.2 Ž(Transducer)
4.3.3 ˸(Couplant)
4.3.4 Ž
4.3.4.1 ǥؽ(Standard Test Block)
4.3.4.1 (Reference Block)
4.4 Ž˻ з
4.4.1 ۼ Ŀ з
4.4.1.1 ݻ(Pulse Echo Technique)
4.4.1.2 (Through Transmission Technique)
4.4.2 ǥ з
4.4.2.1 A-Scan
4.4.2.2 B-Scan
4.4.2.3 C-Scan
5. Ž˻, ET(Eddy Current Testing)
5.1 Ϲ
5.1.1 ˻
5.1.2 Ž˻
5.1.3 Ž˻
5.2 Ž˻ ̷
5.2.1
5.2.2 δϽ(L, Inductance) Ͻ(X, Reactance)
5.2.3 Ǵ(Z, Impedance)
5.2.4 ü
5.2.4.1 ü Ư
5.2.4.2
5.3 Ž
5.3.1 Ž
5.3.2 з
5.3.3 ǥ
5.3.4 ǥ
Chapter IV. װ ı˻ ǹ
1. ںŽ˻ ǹ
1.1.
1.2. Ž ⱸ
1.2.1 ȭ(Stationary Bench Unit)
1.2.2 ũ(Portable Yoke Tester)
1.2.3 ⱸ
1.3
1.3.1 ںŽ
1.3.1.1 ںп
1.3.2
1.3.2.1 Ʈ(ڿܼ) üũ
1.3.2.2 鿭 üũ
1.3.2.3 ܶ
1.3.2.4 ݼ ܶ
1.3.2.5 Ϲ Ȯ
1.3.2.6
1.3.3 ý
1.4 ó
1.4.1 ó
1.4.2 ó
1.5 ˻
1.5.1 ǰ غ
1.5.2 ȭ ȭ
1.5.2.1 ȭ
1.5.2.2 ȭ
1.5.3 ں
1.6 ǵ
1.6.1 ˻
1.7 ó
1.8 ˻
2. ħŽ˻ ǹ
2.1
2.2 ˻
2.2.1 ڿܼ
2.2.2
2.2.3 ȯ ġ( ġ)
2.2.4
2.2.5 ġ
2.2.6 ڿܼ
2.2.7 Ͻ
2.2.8 ý
2.2.9 ħ˻ ŰƮ
2.3
2.3.1 ħ
2.3.2 ȭ()
2.3.3 ڿܼ/鱤
2.3.4 ý
2.4 ó
2.5
2.5.1 ħ˻
2.5.2 ż ħ˻
2.5.3 ģ ȭ ħ˻
2.6 ǵ
2.6.1 ˻
2.6.2 Wipe-off
2.7 ó
2.8 ˻